HPD (ON-OFF)
High Pedal Disable |
AXE and DCX Models Only - Prevent motor controller from
providing power if throttle is applied prior to Key Switch Turned on |
PLUG BRAKE
(ON-OFF)
|
AXE "P" models ONLY with A2 terminal lug. Provides
Plug Braking proportional to throttle position reaching full
"Plugging" (Dynamic Motor Braking) when throttle below 25%. |
| TURBO (ON-OFF) |
Provides higher speed when not in current limit and throttle is at
100% |
1/2 SPEED REVERSE
|
AXE and DCX Models Only - Limits vehicle speed in reverse
based on 50% of forward "Top Speed" setting. |
MAX OUTPUT
CURRENT
(0-100%)
|
50-100% adjustment limits max current supplied to motor. Used
to limit power. (The 400A controller set to 50%=200Amp max)
|
UNDER-VOLTAGE
|
Sets the under-voltage where the unit limits power and eventually shuts off and prevents battery damage.
|
OVER-VOLTAGE
|
Sets the over-voltage shutoff for the controller during excessive regen or overcharging to prevent damage. |
THROTTLE UP RATE
(1-15, Default 4)
|
Determines the rate of controller output power based on an increasing throttle input. Setting 1=slow, 15=Fast. |
THROTTLE DOWN
RATE
(1-15 Default 4)
|
Determines the rate of controller output power based on a decreasing throttle input. Setting 1=slow, 15=Fast
|
BRAKE CURRENT
(0-100%) |
AXE "P" Models - Adjusts the amount of Plug Brake Current as
a percentage of 100A of brake current.
DCX Models - Regeneration Feature is a percentage of possible
current available. |
| TOP SPEED |
Sets the top speed as a percentage of top-speed |